Easco Boiler Corp. | Field Erected & Packaged Quality Steel Boilers A Division of THE A.L. EASTMOND & Sons Corporation
Scotch Marine Boilers
pdf NY City MEA Numbers (PDF - 132KB)
All Categories > SERIES SM5 - LOW PRESSURE STEAM AND HOT WATER "THRU-THE-DOOR" BOILER > Item # SM5-60  

Item # SM5-60, SERIES SM5 - LOW PRESSURE STEAM AND HOT WATER "THRU-THE-DOOR" BOILER


EASCO Series SM5, Modified Scotch Marine, Horizontal Firetube 3-Pass Waterbacked Combustion Systems are manufactured for use in low-pressure steam (15 PSIG) or hot-water (30 to 60 PSIG standard) applications, providing for efficient operation and low cost maintenance.




Lengths  · Widths  · Heights  · Boiler Service Connection Locations  · Boiler Service Connection Sizes  · Specifications  · Ratings & Capacity Data

Lengths

A-Overall

169-7/8 in

B-Shell

115-3/4 in

C-Base Frame

129-5/8 in

E-Minimum Tube Pull Clearance

121-3/4 in

F-Minimum Rear Smoke Box Door Clearance

15 in


Widths

G-Overall with Steam Trim

43 in

H-with 2" Insulation

34 in

l-Base Frame (Package)

34 in

N-Front Smoke Box

11-3/8 in


Heights

O-Overall

82 in

P-Base to Furnace C.L.

24-7/8 in

Q-Base Frame

6 in

R-Base to Boiler C.L.

39-7/8 in


Boiler Service Connection Locations

U-Base to Flue Gas Outlet

64-7/8 in

V-Base to Supply Outlet

74-1/4 in

W-Length from Front Tubesheet to Center of Supply Conn.

57-7/8 in

X-Rear Smoke Box Outlet Center Line

8 in

Y-Length from Front Tubesheet to Center of Return Conn.

91-5/8 in

Z-Height from Base to Return Connection

30-7/8 in


Boiler Service Connection Sizes

a-Supply, Steam/Hot Water

6 in

b-Flue Gas Vent

12 in

c-Safety Relief Valve(s)

2 in

d-Control Header

1 in

e-Surface Blowdown

2 in

f-Washout

2 in

g-Feedwater/Return, Steam/Hot Water

3 in

h-Bottom Blowdown

2 in

i-Aquastat

3/4 in


Specifications

Shipping Weight Dry Packaged (Approx.)

5278 lb

Water Content Steam Boiler

378 gal

Water Content Hot Water Boiler

487 gal

General Service Access & Fireside Sampling

Manhole
Access/Observation
Furnace Access Door
Furnace Draft Sample
Flue Gas Outlet Cleanout Access
Furnace Observation Port
Sequence Draft Sample
Combustion Relief Mechanism
Rear Smoke Box Access
Front Smoke Box Access


Ratings & Capacity Data

Gross Output Boiler Horsepower

60 hp

Gross Output Steam/Hot Water

2008 mbh

Gross Output Steam, from and at 212 degrees F

2070 lb/hr

Maximum Firing Rate Light Oil, 140 MBH/Gal

17.5 gph

Maximum Firing Rate Natural Gas

2449 mbh

Heating Surface Fireside

300 ft²


    Download PDF Download PDF   
    border="0" Printable Page  
    Email Email This Page  
    Save To Favorites Save To Favorites
  

 MORE IMAGES 

·  sm5-front-view

·  sm5-packaged-boiler-assembly-right-elevation

·  sm5-rear-view


Site created by ThomasNet Web Solutions and powered by Navigator Platform